background image
Redundant Links with STP
201
There is a mismatch in trunking, duplex, and STP port priority. All of the
ports must be configured the same for EtherChannel to work.
To view the configuration of a port, use the show port capability
slot/port
command:
Todd5000> (enable) sh port cap 1/1
Model WS-X5509
Port 1/1
Type 100BaseTX
Speed 100
Duplex half,full
Trunk encap type ISL
Trunk mode on,off,desirable,auto,nonegotiate
Channel 1/1-2
Broadcast suppression percentage(0-100)
Flow control no
Security yes
Membership static,dynamic
Fast start yes
Rewrite no
Todd5000> (enable)
The preceding output shows the card model number and the configura-
tion of the port. The easiest way for us to make sure all the ports we want to
channel are configured the same is to just clear the configuration. We're not
suggesting that you just clear your config whenever any problems come up,
but the configuration we created in this chapter is pretty extensive, and it's
just easier to just clear it out of the switch to perform the next function:
Todd5000> (enable) clear config all
This command will clear all configuration in NVRAM.
This command will cause ifIndex to be reassigned on the
next system startup.
Do you want to continue (y/n) [n]? y
........
.................
System configuration cleared.
Console> (enable)
Copyright ©2000 SYBEX , Inc., Alameda, CA
www.sybex.com