background image
Catalyst Troubleshooting Tools
579
show test
The status of the switch, including interface cards, power supplies, and mem-
ory, is available by using the show test command.
Observe that the first show test output reports only the status of the
supervisor module and no information specific to the other modules.
Switch_A> (enable) show test
Environmental Status (. = Pass, F = Fail, U = Unknown)
PS (3.3V): . PS (12V): . PS (24V): . PS1: .
PS2: .
Temperature: . Fan: . Clock(A/B): A Chassis-
Ser- EEPROM: .
Module 1 : 2-port 100BaseFX MM Supervisor
Network Management Processor (NMP) Status: (. = Pass, F =
Fail, U = Unknown)
ROM: . Flash-EEPROM: . Ser-EEPROM: . NVRAM: . MCP
Comm: .
EARL Status :
NewLearnTest: .
IndexLearnTest: .
DontForwardTest: .
MonitorTest .
DontLearn: .
FlushPacket: .
ConditionalLearn: .
EarlLearnDiscard: .
EarlTrapTest: .
LCP Diag Status for Module 1 (. = Pass, F = Fail, N = N/A)
CPU : . Sprom : . Bootcsum : . Archsum : N
RAM : . LTL : . CBL : . DPRAM :
.SAMBA : .
Saints : . Pkt Bufs : . Repeater : N FLASH :
N
Copyright ©2000 SYBEX , Inc., Alameda, CA