background image
Catalyst Troubleshooting Tools
577
!
#drip
set tokenring reduction enable
set tokenring distrib-crf disable
!
#module 1 : 2-port 100BaseFX MM Supervisor
set module name 1
set vlan 1 1/1-2
set port channel 1/1-2 off
set port channel 1/1-2 auto
set port enable 1/1-2
set port level 1/1-2 normal
set port duplex 1/1-2 half
set port trap 1/1-2 enable
set port name 1/1-2
set port security 1/1-2 disable
set port broadcast 1/1-2 100%
set port membership 1/1-2 static
set cdp enable 1/1-2
set cdp interval 1/1-2 60
set trunk 1/1 auto 1-1005
set trunk 1/2 auto 1-1005
set spantree portfast 1/1-2 disable
set spantree portcost 1/1-2 19
set spantree portpri 1/1-2 32
set spantree portvlanpri 1/1 0
set spantree portvlanpri 1/2 0
set spantree portvlancost 1/1 cost 18
set spantree portvlancost 1/2 cost 18
!
#module 2 : 24-port 10/100BaseTX Ethernet
set module name 2
set module enable 2
set vlan 1 2/1-24
set port enable 2/1-24
set port level 2/1-24 normal
Copyright ©2000 SYBEX , Inc., Alameda, CA
www.sybex.com