background image
Catalyst Troubleshooting Tools
575
set vlan 1004 name fddinet-default type fddinet mtu 1500
said 101004 state active bridge 0x0 stp ieee
set vlan 1005 name trnet-default type trbrf mtu 1500 said
101005 state active bridge 0x0 stp ieee
set vlan 1003 name Token-Ring-default type trcrf mtu 1500
said 101003 state active parent 0 ring 0x0 mode srb
aremaxhop 7 stemaxhop 7
!
#spantree
#uplinkfast groups
set spantree uplinkfast disable
#vlan 1
set spantree enable 1
set spantree fwddelay 15 1
set spantree hello 2 1
set spantree maxage 20 1
set spantree priority 32768 1
#vlan 1003
set spantree enable 1003
set spantree fwddelay 4 1003
set spantree hello 2 1003
set spantree maxage 10 1003
set spantree priority 32768 1003
set spantree portstate 1003 auto 0
set spantree portcost 1003 80
set spantree portpri 1003 4
set spantree portfast 1003 disable
#vlan 1005
set spantree enable 1005
set spantree fwddelay 15 1005
set spantree hello 2 1005
set spantree maxage 20 1005
set spantree priority 32768 1005
set spantree multicast-address 1005 ieee
!
#cgmp
set cgmp disable
Copyright ©2000 SYBEX , Inc., Alameda, CA