background image
ISDN Troubleshooting Commands
445
Bottom#show interface bri0 1
BRI0:1 is down, line protocol is down
Hardware is BRI with U interface and POTS
MTU 1500 bytes, BW 64Kbit, DLY 20000 usec,
reliablility 255/255, txload 1/255, rxload 1/255
Encapsulation PPP, loopback not set, keepalive set (10
sec)
LCP Closed, multilink Closed
Closed: BACP, CDPCP, IPCP
Last input 00:02:09, output 00:02:09, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
219 packets input, 3320 bytes, 0 no buffer
Received 219 broadcasts, 0 runts, 0 giants, 0
throttles
146 input errors, 9 CRC, 59 frame, 0 overrun, 0
ignored, 78 abort
279 packets output, 16195 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped
out
15 carrier transitions
show controller bri
The interface hardware controller information is displayed with the show
controller bri
command. This command is most useful for troubleshooting
with Cisco's TAC, but some information can assist the administrator. Most
important, the status of the interface, in this case a U type connection, and the
superframe error counter are available in this show command.
Bottom#show controller bri
BRI unit 0:BRI unit 0 with U interface and POTS:
Layer 1 internal state is ACTIVATED
Copyright ©2000 SYBEX , Inc., Alameda, CA