background image
410
Chapter 7
Troubleshooting Serial Line and Frame Relay Connectivity
The StEnq, myseq, and yourseen are similar to the data provided by the
serial
debug command. The newly introduced fields are as follows:
RT IE This is a Report Type Information Element.
KA IE This is a Keepalive Information Element.
This debug command does not generate a great deal of output, as you can
see. Therefore, it can be used even during high traffic times. Some outputs
will include more information than the sample displayed previously. Addi-
tional information includes clocking, PVC, and Committed Information
Rate detail.
debug frame-relay events
Data provided by this command is useful because it gives details about
protocols and applications using the DLCI. A sample follows. The (i) and (o)
specify inbound and outbound traffic:
Router_A#debug frame-relay events
Serial3(i): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
Serial3.6(o): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
Serial3(i): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
Serial3.6(o): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
Serial0.2(o): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
Serial3(i): dlci 1023(0xFCF1), pkt type 0x309,
datagramsize 13
The pkt type is used to distinguish the packet type that transits the
DLCI. Several different packet types may appear in the pkt type field. The
packet type tells you which applications are on the circuit.
Copyright ©2000 SYBEX , Inc., Alameda, CA