282
Chapter 5
Applying Cisco's Diagnostic Tools
password aloha
login
!
end
Router_A#
Everything seems to be configured properly. Now, move on to the console
of Router B. First, issue a show interface command:
Router_B#show interface to0
TokenRing0 is up, line protocol is down
Hardware is TMS380, address is 0007.787c.e1cb (bia
0007.787c.e1cb)
Internet address is 172.16.30.2, subnet mask is
255.255.255.0
MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec, rely 255/
255, load 1/255
Encapsulation SNAP, loopback not set, keepalive set (10
sec)
ARP type: SNAP, ARP Timeout 04:00:00
Ring speed: 16 Mbps
Single ring node, Source Route Transparent Bridge
capable
Ethernet Transit OUI: 0x000000
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored,
0 abort
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped
out
2 transitions