background image
Troubleshooting Ethernet Problems
273
2858 packets output, 3943213 bytes, 0 underruns
0 output errors, 443 collisions, 0 interface resets
0 babbles, 0 late collision, 471 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped
out
Router_C#show int ethernet 0/1
Ethernet0/1 is up, line protocol is up
Hardware is Lance, address is 0000.0c47.abea (bia
0000.0c47.abea)
Internet address is 172.16.60.1/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/
255, load 46/255
Encapsulation ARPA, loopback not set, keepalive set (10
sec)
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 00:00:37
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1209000 bits/sec, 620 packets/sec
5 minute output rate 1819000 bits/sec, 477 packets/sec
21386 packets input, 3979009 bytes, 0 no buffer
Received 9 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored,
0 abort
0 input packets with dribble condition detected
5590 packets output, 8237684 bytes, 0 underruns
0 output errors, 889 collisions, 0 interface resets
0 babbles, 0 late collision, 1006 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped
out
Router_C#show int ethernet 0/1
Ethernet0/1 is up, line protocol is up
Hardware is Lance, address is 0000.0c47.abea (bia
0000.0c47.abea)
Copyright ©2000 SYBEX , Inc., Alameda, CA
www.sybex.com