background image
Identifying and Resolving Generic Router Problems
259
!
end
Router_C#
The show interface results should be reviewed before the configuration
of Router B is displayed. The only interface that is of concern is the one that
connects the two routers--interface Ethernet 0/0. The results are shown as
follows. As depicted, interface Ethernet 0/0 is up and functioning. This is
proved by using the ping command.
Router_C>show interface ethernet0/0
Ethernet0/0 is up, line protocol is up
Hardware is AmdP2, address is 0010.7bd9.2880 (bia
0010.7bd9.2880)
Internet address is 172.16.50.2/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/
255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10
sec)
ARP type: ARPA, ARP Timeout 04:00:00
Last input 02:54:40, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
1006 packets input, 90611 bytes, 0 no buffer
Received 990 broadcasts, 0 runts, 0 giants, 0
throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored,
0 abort
0 input packets with dribble condition detected
4935 packets output, 402703 bytes, 0 underruns
0 output errors, 0 collisions, 2 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped
out