background image
250
Chapter 5
Applying Cisco's Diagnostic Tools
Router_A(config-if)#ip address 172.16.30.1 255.255.255.0
Router_A(config)#interface serial 0/0
Router_A(config-if)#no shutdown
Router_A(config-if)#^Z
Router_A#
Router_A#show interface ethernet 0/0
Ethernet0/0 is up, line protocol is up
Hardware is AmdP2, address is 0010.7bd9.2880 (bia
0010.7bd9.2880)
Internet address is 172.16.10.1/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/
255, load 29/255
Encapsulation ARPA, loopback not set, keepalive set (10
sec)
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 1/75, 0 drops
5 minute input rate 509000 bits/sec, 215 packets/sec
5 minute output rate 1167000 bits/sec, 315 packets/sec
25800 packets input, 20685400 bytes, 0 no buffer
Received 3235 broadcasts, 0 runts, 0 giants
6 input errors, 1 CRC, 5 frame, 0 overrun, 640
ignored, 0 abort
0 input packets with dribble condition detected
37800 packets output, 30249800 bytes, 0 underruns
283 output errors, 4 collisions, 2 interface
resets
0 babbles, 0 late collision, 0 deferred
283 lost carrier, 0 no carrier
0 output buffers copied, 0 interrupts, 0 failures
Router_A#show interface serial 0/0
Serial0/0 is up, line protocol is up
Hardware is PowerQUICC Serial
Internet address is 172.16.20.5/30
Copyright ©2000 SYBEX , Inc., Alameda, CA