background image
Troubleshooting Commands
219
Record route: 172.16.1.2 172.16.0.13 172.16.12.1
172.16.12.93 172.16.0.14 172.16.0.21 172.16.1.2 <*>
0.0.0.0 0.0.0.0
End of list
Reply to request 1 (4 ms). Received packet has options
Total option bytes= 40, padded length=40
Record route: 172.16.1.2 172.16.0.13 172.16.12.1
172.16.12.93 172.16.0.14 172.16.0.21 172.16.1.2 <*>
0.0.0.0 0.0.0.0
End of list
Reply to request 2 (4 ms). Received packet has options
Total option bytes= 40, padded length=40
Record route: 172.16.1.2 172.16.0.13 172.16.12.1
172.16.12.93 172.16.0.14 172.16.0.21 172.16.1.2 <*>
0.0.0.0 0.0.0.0
End of list
Reply to request 3 (1 ms). Received packet has options
Total option bytes= 40, padded length=40
Record route: 172.16.1.2 172.16.0.13 172.16.12.1
172.16.12.93 172.16.0.14 172.16.0.21 172.16.1.2 <*>
0.0.0.0 0.0.0.0
End of list
Reply to request 4 (1 ms). Received packet has options
Total option bytes= 40, padded length=40
Record route: 172.16.1.2 172.16.0.13 172.16.12.1
172.16.12.93 172.16.0.14 172.16.0.21 172.16.1.2 <*>
0.0.0.0 0.0.0.0
End of list
Success rate is 100 percent (5/5), round-trip min/avg/max
= 1/2/4 ms
Router_B#
The character echoes have the same meaning as with the user mode of the
ping
command. Let's discuss the extended dialog. The extended ping mode
is accessed by just typing the word ping. The default protocol is IP. The next
field is the target IP address. The default values are located within the brack-
ets of each dialog question. The repeat count is five ICMP requests. The next
field is the datagram size, followed by the timeout.
Copyright ©2000 SYBEX , Inc., Alameda, CA
www.sybex.com