background image
694 Chapter 9: Scenarios for Final Preparation
Using Examples 9-19 through 9-22 as references, answer the following questions:
1
The ping of 170.1.5.2 (R2's E0 interface) from R3 was successful (refer to Example 9-21).
Why was it successful if the access lists in R1 are enabled as shown in its configuration?
2
Describe the SAP update entering R1 over its S0.2 subinterface. How many services are
described?
3
What show commands could be executed on R4 to display the IP and IPX addresses
of R1?
R 3 [07/01] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 4 [13/02] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 5 [13/02] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 6 [13/02] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 7 [13/02] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 10 [07/01] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 12 [07/01] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 101 [08/03] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 102 [08/03] via 14.0200.aaaa.aaaa, 34s, Se0.1
R 103 [14/04] via 14.0200.aaaa.aaaa, 34s, Se0.1
R4#show cdp neighbor detail
-------------------------
Device ID: R1
Entry address(es):
IP address: 170.1.14.1
Novell address: 14.0200.aaaa.aaaa
Platform: Cisco 2500, Capabilities: Router
Interface: Serial0.1, Port ID (outgoing port): Serial0.4
Holdtime : 178 sec
Version :
Cisco Internetwork Operating System Software
IOS (tm) 2500 Software (C2500-AINR-L), Version 11.2(11), RELEASE SOFTWARE (fc1)
Copyright 1986-1997 by Cisco Systems, Inc.
Compiled Mon 29-Dec-97 18:47 by ckralik
R4#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
DLCI = 301, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.1
input pkts 85 output pkts 63 in bytes 14086
out bytes 8464 dropped pkts 0 in FECN pkts 0
in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
in DE pkts 0 out DE pkts 0
out bcast pkts 53 out bcast bytes 7614
pvc create time 00:18:40, last time pvc status changed 00:18:40
Example 9-22
Scenario 9-3, Part C--R4 show and debug Output (Continued)
ch09.fm Page 694 Monday, March 20, 2000 5:23 PM