background image
Scenario 9-2 671
R3#show ip arp
Protocol Address Age (min) Hardware Addr Type Interface
Internet 168.11.13.103 - 0000.0c89.b1b0 SNAP Ethernet0
R3#show ip route
Codes: C - connected, S - static, I - IGRP, R - RIP, M - mobile, B - BGP
D - EIGRP, EX - EIGRP external, O - OSPF, IA - OSPF inter area
N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2
E1 - OSPF external type 1, E2 - OSPF external type 2, E - EGP
i - IS-IS, L1 - IS-IS level-1, L2 - IS-IS level-2, * - candidate default
U - per-user static route, o - ODR
Gateway of last resort is not set
168.11.0.0/26 is subnetted, 4 subnets
C 168.11.123.192 is directly connected, Serial0
I 168.11.11.64 [100/8539] via 168.11.123.201, 00:00:06, Serial0
C 168.11.13. 64 is directly connected, Ethernet0
I 168.11.12. 64 [100/8539] via 168.11.123.202, 00:00:46, Serial0
R3#ping 168.11.11.80
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 168.11.11.80, timeout is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 76/76/76 ms
R3#trace 168.11.11.80
Type escape sequence to abort.
Tracing the route to 168.11.11.80
1 168.11.123.201 44 msec 44 msec 44 msec
2 168.11.11.250 44 msec * 40 msec
R3#show ipx servers
Codes: S - Static, P - Periodic, E - EIGRP, N - NLSP, H - Holddown, + = detail
3 Total IPX Servers
Table ordering is based on routing and server info
Type Name Net Address Port Route Hops Itf
P 4 Server1 101.0000.0000.0001:0451 8/03 3 Se0
P 4 Server2 102.0000.0000.0001:0451 8/03 3 Se0
P 4 Server3 103.0000.0000.0001:0451 2/02 2 E0
R3#show frame-relay map
Serial0 (up): ipx 123.0200.aaaa.aaaa dlci 501(0x1F5,0x7C50), dynamic,
broadcast,, status defined, active
Serial0 (up): ipx 123.0200.bbbb.bbbb dlci 502(0x1F6,0x7C60), dynamic,
broadcast,, status defined, active
Example 9-14
Scenario 9-2, Part C--R3 show and debug Output (Continued)
continues
ch09.fm Page 671 Monday, March 20, 2000 5:23 PM