background image
Scenario 8-2: Frame Relay Verification 617
Invalid Information ID 0 Invalid Report IE Len 0
Invalid Report Request 0 Invalid Keep IE Len 0
Num Status Enq. Sent 84 Num Status msgs Rcvd 84
Num Update Status Rcvd 0 Num Status Timeouts 0
Example 8-39
Boston Command Output, Scenario 8-2
Boston#show interface s 0.1
Serial0.1 is up, line protocol is up
Hardware is HD64570
Internet address is 168.10.204.4/24
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
Encapsulation FRAME-RELAY
Boston#show cdp neighbor detail
-------------------------
Device ID: Atlanta
Entry address(es):
IP address: 168.10.204.1
Novell address: 204.0200.aaaa.aaaa
Platform: Cisco 2500, Capabilities: Router
Interface: Serial0.1, Port ID (outgoing port): Serial0.3
Holdtime : 125 sec
Version :
Cisco Internetwork Operating System Software
IOS (tm) 2500 Software (C2500-AINR-L), Version 11.2(11), RELEASE SOFTWARE (fc1)
Copyright 1986-1997 by Cisco Systems, Inc.
Compiled Mon 29-Dec-97 18:47 by ckralik
Boston#show frame-relay map
Serial0.1 (up): point-to-point dlci, dlci 51(0x33,0xC30), broadcast, IETF
status defined, active
Boston#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
DLCI = 51, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.1
input pkts 65 output pkts 54 in bytes 8475
out bytes 6906 dropped pkts 1 in FECN pkts 0
in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
in DE pkts 0 out DE pkts 0
out bcast pkts 52 out bcast bytes 6792
pvc create time 00:15:43, last time pvc status changed 00:07:54
Num Update Status Rcvd 0 Num Status Timeouts 0
Example 8-38
Nashville Command Output, Scenario 8-2 (Continued)
ch08.fm Page 617 Monday, March 20, 2000 5:17 PM