background image
Scenario 8-2: Frame Relay Verification 615
Serial0(out): StEnq, myseq 6, yourseen 5, DTE up
datagramstart = 0x45B25C, datagramsize = 13
FR encap = 0xFCF10309
00 75 01 01 01 03 02 06 05
Serial0(in): Status, myseq 6
RT IE 1, length 1, type 1
KA IE 3, length 2, yourseq 6 , myseq 6
Example 8-37
Charlotte Command Output, Scenario 8-2
Charlotte#show interface s 0.1
Serial0.1 is up, line protocol is up
Hardware is HD64570
Internet address is 168.10.202.2/24
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
Encapsulation FRAME-RELAY
Charlotte#show cdp neighbor detail
-------------------------
Device ID: Atlanta
Entry address(es):
IP address: 168.10.202.1
Novell address: 202.0200.aaaa.aaaa
Platform: Cisco 2500, Capabilities: Router
Interface: Serial0.1, Port ID (outgoing port): Serial0.1
Holdtime : 164 sec
Version :
Cisco Internetwork Operating System Software
IOS (tm) 2500 Software (C2500-AINR-L), Version 11.2(11), RELEASE SOFTWARE (fc1)
Copyright 1986-1997 by Cisco Systems, Inc.
Compiled Mon 29-Dec-97 18:47 by ckralik
Charlotte#show frame-relay map
Serial0.1 (up): point-to-point dlci, dlci 51(0x33,0xC30), broadcast
status defined, active
Charlotte#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
DLCI = 51, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.1
input pkts 36 output pkts 28 in bytes 4506
out bytes 2862 dropped pkts 1 in FECN pkts 0
in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
in DE pkts 0 out DE pkts 0
out bcast pkts 26 out bcast bytes 2774
pvc create time 00:08:54, last time pvc status changed 00:01:26
Charlotte#show frame-relay lmi
Example 8-36
Atlanta Command Output, Scenario 8-2 (Continued)
continues
ch08.fm Page 615 Monday, March 20, 2000 5:17 PM