background image
434 Chapter 6: Routing
Assuming the details established in Figure 6-25, Table 6-32, and Example 6-24, Example 6-25,
and Example 6-26 for Scenario 6-3, complete or answer the following:
1
Examining the show commands on the various routers, complete Table 6-32 with the
subnet numbers and broadcast addresses used in this network.
Serial0 170.1.1.3 YES NVRAM up up
Serial1 180.1.1.253 YES NVRAM administratively down down
Ethernet0 170.1.103.3 YES NVRAM up up

Raleigh#show ip protocol
Routing Protocol is "igrp 4"
Sending updates every 90 seconds, next due in 56 seconds
Invalid after 270 seconds, hold down 280, flushed after 630
Outgoing update filter list for all interfaces is not set
Incoming update filter list for all interfaces is not set
Default networks flagged in outgoing updates
Default networks accepted from incoming updates
IGRP metric weight K1=1, K2=0, K3=1, K4=0, K5=0
IGRP maximum hopcount 100
IGRP maximum metric variance 1
Redistributing: igrp 4
Routing for Networks:
170.1.0.0
Routing Information Sources:
Gateway Distance Last Update
170.1.1.2 100 00:00:20
170.1.1.1 100 00:00:53
Distance: (default is 100)
Raleigh#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
DLCI = 47, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0
input pkts 36 output pkts 35 in bytes 3674
out bytes 3436 dropped pkts 0 in FECN pkts 0
in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
in DE pkts 0 out DE pkts 0
out bcast pkts 34 out bcast bytes 3358
pvc create time 00:22:07, last time pvc status changed 00:21:58
DLCI = 48, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0
input pkts 35 output pkts 35 in bytes 3444
out bytes 3422 dropped pkts 0 in FECN pkts 0
in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
in DE pkts 0 out DE pkts 0
out bcast pkts 34 out bcast bytes 3358
pvc create time 00:22:08, last time pvc status changed 00:21:58
Example 6-26
Scenario 6-3, show Commands on Router Raleigh (Continued)
ch06.fm Page 434 Monday, March 20, 2000 5:11 PM