background image
Scenario 5-1: IP Addressing and Subnet Calculation 329
5 minute output rate 0 bits/sec, 0 packets/sec
125 packets input, 7634 bytes, 0 no buffer
Received 124 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
161 packets output, 9575 bytes, 0 underruns
0 output errors, 0 collisions, 1 interface resets
0 output buffer failures, 0 output buffers swapped out
4 carrier transitions
DCD=up DSR=up DTR=up RTS=up CTS=up
Ethernet0 is up, line protocol is up
Hardware is MCI Ethernet, address is 0000.0c55.AB44 (bia 0000.0c55.AB44)
Internet address is 199.1.1.33/27
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
ARP type: ARPA, PROBE, ARP Timeout 4:00:00 Last input 0:00:00, output
0:00:00, output hang never
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
Five minute input rate 4000 bits/sec, 4 packets/sec
Five minute output rate 6000 bits/sec, 6 packets/sec
22197 packets input, 309992 bytes, 0 no buffer
Received 2343 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
4456 packets output, 145765 bytes, 0 underruns
3 output errors, 10 collisions, 2 interface resets, 0 restarts
fred>show ip route
Codes: C - connected, S - static, I - IGRP, R - RIP, M - mobile, B - BGP
D - EIGRP, EX - EIGRP external, O - OSPF, IA - OSPF inter area
N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2
E1 - OSPF external type 1, E2 - OSPF external type 2, E - EGP
i - IS-IS, L1 - IS-IS level-1, L2 - IS-IS level-2, * - candidate default
U - per-user static route, o - ODR
Gateway of last resort is not set
199.1.1.0/27 is subnetted, 6 subnets
R 199.1.1.192 [120/1] via 199.1.1.98, 00:00:01, Serial1
R 199.1.1.128 [120/1] via 199.1.1.98, 00:00:01, Serial1
[120/1] via 199.1.1.66, 00:00:20, Serial0
R 199.1.1.160 [120/1] via 199.1.1.66, 00:00:20, Serial0
C 199.1.1.64 is directly connected, Serial0
C 199.1.1.96 is directly connected, Serial1
C 199.1.1.32 is directly connected, Ethernet0

fred>show ip protocol
Routing Protocol is "rip"
Sending updates every 30 seconds, next due in 23 seconds
Invalid after 180 seconds, hold down 180, flushed after 240
Outgoing update filter list for all interfaces is not set
Incoming update filter list for all interfaces is not set
Example 5-28
Command Output on Router Fred (Continued)
continues
ch05.fm Page 329 Monday, March 20, 2000 5:06 PM