background image
272
Chapter 5
Applying Cisco's Diagnostic Tools
Last clearing of "show interface" counters 00:00:05
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1259000 bits/sec, 629 packets/sec
5 minute output rate 1822000 bits/sec, 486 packets/sec
3476 packets input, 455808 bytes, 0 no buffer
Received 2 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored,
0 abort
0 input packets with dribble condition detected
1165 packets output, 1667097 bytes, 0 underruns
0 output errors, 175 collisions, 0 interface resets
0 babbles, 0 late collision, 182 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped
out
Router_C#show int ethernet 0/1
Ethernet0/1 is up, line protocol is up
Hardware is Lance, address is 0000.0c47.abea (bia
0000.0c47.abea)
Internet address is 172.16.60.1/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/
255, load 46/255
Encapsulation ARPA, loopback not set, keepalive set (10
sec)
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 00:00:16
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1243000 bits/sec, 627 packets/sec
5 minute output rate 1826000 bits/sec, 484 packets/sec
9872 packets input, 1760499 bytes, 0 no buffer
Received 4 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored,
0 abort
0 input packets with dribble condition detected
Copyright ©2000 SYBEX , Inc., Alameda, CA
www.sybex.com